CONDENSATION IN POLYPROPYLENE

PPs Series
MAIN FEATURES
  • Flex-PPs series, polypropylene flexible single wall;
  • PPs rigid series
  • Polypropylene rigid single wall, in white colour;
  • Product certified for condensation generators (T120°)
  • EN 14241-1 certified sealing ring;
  • Complete range;
Material specification
Inside diameter(mm): 60•80•110•125•160•200•250•315
Inner surface 1.5 mm minimum nominal thickness
Homopolymer polypropylene quality
Surface thermal resistance m2K/W at 200°C Without insulation = 0.00
Sealing ring Profiled ring seal with three black silicone sealing lips
conforming to UNI EN 14241/1
Roughness 1 mm average value
General information
Installation Internal Yes
External NO it is neither rain nor UV ray proof
Fields of application Ducts, chimneys, smoke ducts, manifolds and flues connected to
blown air, atmospheric, condensation and pressurised boilers, type B and C appliances, condensation, kitchen hoods, ovens and ventilation ducts
Permitted fuels T120 Gas, LPG and Diesel oil with a sulphur content =0.2% in mass
Conservation In environments with a non-corrosive atmosphere
Product warranty As per the 99/44/EC directive
Dangerous substances None
Freezing-thawing resistance Requirement not met
Accidental contact Protective shields must be used when surface temperature
is greater than 70°C
Storage Do not store the material near ferrous materials, premises must be
dry and protected against the elements
Usage limits Environments such as laundries, dyeworks, furrier’s, print shops, beauty salons or
places with halogenated or chromate vapors
Product designation as per the EN 1447-1 standard Chimney system
No. of the standard EN 1447-1
Temperature level T120
Pressure level P1/H1
Resistance to condensation W
Resistance to corrosion 2
Place of installation I
Resistance to fire from inside and distance from combustible materials O(20)
Reaction to fire D
Wall class L

 

Performance required according to the designation
Temperature level T120 working with a nominal fumes temperature at less than 120°C
Pressure level P1

 

H1

working with a positive and negative pressure up to 200Pa. Permitted loss less than 0.006 l/m2
working with a positive and negative pressure up to 5000Pa. Permitted loss less than 0.006l/sm2
Resistance to condensation W working with moist and dry fumes
Resistance to corrosion V2 working with Gas, LPG and Diesel oil with a sulphur content ≤ 0.2% in mass
Place of installation I only inside buildings
Reaction to fire D on a scale that goes from F (products that cannot be classified as fire resistant) to A1 (products that in no way contribute to any phases of a fire). Class D are products that can resist the action of a small flame for a short length of time with no substantial spreading of the fire.
Wall class L no external protection
Resistance to fire from inside O not fire resistant from inside
Distance from combustible materials (20) (20)=minimum 20mm;

INSTALLATION INSTRUCTIONS

PPS-installazione

  • Position the elements with the female socket facing up.
  • Use the sliding element for the male-female connection and always maintain a 3° slanting angle on horizontal installations.
  • Observe the compression loads and the non-vertical installations.

ESSENTIAL FEATURES

Resistance to the wind load:

  • Distance between wall brackets: NPD m
  • Free length from the last bracket: 3 m

Compressive strength:

  • Linear elements’ maximum load: 30m
  • Maximum load of a straight fitting at 90°: 30m
  • Maximum load of the wall chimney support

30m Tensile and bending strength (linear elements):

  • Maximum load at traction (element connection means and chimney connections): NPDm
  • Non-vertical installations: NPD
  • Non-vertical installations: distance between wall chimney supports = NPD

Traction and bending strength (non-linear elements):

  • Non-vertical installations: NPD

FLUE SYSTEM MAINTENANCE

Scheduled maintenance carried out by qualified personnel:

  • Unless standards dictate otherwise or different agreements are reached with the user, the following maintenance schedule is advisable:
    • gaseous fuels: 1 / year;
    • liquid fuels: 1 / 6 months;
  • Clean the smoke duct with a soft plastic brush or sponge as well as the equipment compartment for pipe supply and ventilation, the inspection fitting and chimney and also make sure the smoke/fumes and condensates etc., are flowing freely.