Stainless steel AISI 316L flexible liner with smooth inner wall

Technical Data
Material specification
Internal diameter (mm): 80 • 100 • 120 • 130 • 140 • 150 • 160 • 180 • 200 • 220 • 250 • 300
Inner wallNominal thickness: 0.1 mm

Grade 1.4404 (AISI 316L stainless steel)

Wall thermal resistance m²K/W at 200°C:
Without insulation = 0.00
Roughness: average value 1 mm
General information
InstallationInternal use: intended for lining chimneys/flues/technical shafts.

External: No, not resistant to rainwater penetration

Applications: Ducts, chimneys, flue pipes, connectors, and flue systems connected to forced-air boilers, atmospheric and pressurized boilers, type B and C appliances, condensing units, fireplaces, stoves, kitchen hoods, ovens, and ventilation ducts
Permitted fuelsT200: Gas, Diesel, LPG, Pellet

T600: Gas, Diesel, LPG, Pellet, and Wood

Storage: In environments where the atmosphere is non-corrosive
Product warranty: In accordance with Directive 99/44/EC
Hazardous substances: None
Freeze–thaw resistance: Compliant with UNI EN 1856-1
Accidental contact
No accidental contact is possible, as it is intended for lining chimneys, flues, and technical shafts.
Storage: Do not store the material near ferrous materials; environments must be dry and protected from weather exposure
Limitations of use: The use of stainless steel flue systems is not recommended in environments such as laundries, dry cleaners, furriers, printing facilities, beauty salons, or in any areas where halogenated or chromated vapors are present
Product designation according to EN 1856-2*
Duct.
Standard number
EN 1856-2
Temperature rating
T200
Pressure rating
P1
Condensate resistance
W
Corrosion resistance
V2
Internal wall thickness L50010
Fire resistance from the inside and distance from combustible materials: O

for diameters 80 mm – 160 mm.

Product designation according to EN 1856-2 standard: Flue gas duct
Standard number
EN 1856-2
Temperature level: T450
Pressure rating
N1
Condensate resistance
W
Corrosion resistance
V2
Internal wall thickness L50010
Fire resistance from inside and distance to combustible materials
G
Performance requirements according to the designation
Temperature levelT200

T450

Operation with nominal flue gas temperature lower than 200°C

Operation with nominal flue gas temperature lower than 450°C

Pressure levelP1

N1

Operation with positive and negative pressure up to 200 Pa.
Permissible leakage less than 0.006 l/m²

Operation with positive and negative pressure up to 40 Pa.
Permissible leakage less than 2.0 l/s·m²

Condensate resistanceW

W

Operation with wet and dry flue gases

Operation with wet and dry flue gases

Corrosion resistance
V2 – suitable for operation with gas, diesel oil, LPG, pellets, and wood.
Internal wall specification: L50, 1.4404 (AISI 316L stainless steel)
Internal wall thickness: 0.10 mm (nominal thickness)
Internal fire resistance0

G

No internal fire resistance

Internal fire-resistant

Distance from combustible materials – The installer determines the most suitable installation distance based on the thickness and characteristics of the shaft/technical duct.

INSTALLATION INSTRUCTIONS

  • Position the elements as indicated by the arrow stamped on the component.
  • For connection of the Flex series with other series to achieve the designation T200_P1_W, use the appropriate gasketed accessories of item 4954 (push-fit connector with gasket between threaded Flex and rigid single-wall pipe).
  • In case of use T450_N1_D, use item 4951 (push-fit connector between threaded Flex and rigid single-wall pipe).

ESSENTIAL CHARACTERISTICS

Wind load resistance:

  • Distance between wall brackets: NPD m
  • Free length from the last bracket: NPD m

Compression resistance:

  • Maximum load of linear elements: 15 m

Note: The values above refer to the worst-case condition. For more information, see the Mechanical Resistance Table.

Tensile and bending resistance (straight elements):

  • Maximum tensile load (connection means of chimney elements and fittings): 15 m
  • Non-vertical installations: max. 90°

Torsional resistance:

  • 7,6 kg m

Note: The values above refer to the worst-case condition. For more information, see the Mechanical Resistance Table.

FLUE SYSTEM MAINTENANCE


Scheduled maintenance carried out by qualified personnel:

  • Unless otherwise required by regulations or agreed with users, the following maintenance intervals are recommended:
    • Gaseous fuels: once per year;
    • Liquid fuels: once every 6 months;
    • Solid fuels: once per month.
  • Cleaning using a soft plastic brush or sponge of the flue pipe, the technical compartment for air supply and ventilation of the ducts, the inspection connection, the chimney cap; checking the free flow of flue gases and condensate, etc.

Contact us

Request information or a customized quote

"*" indicates required fields

Dati personali*

Lasciaci il tuo numero di telefono. Ti chiameremo non appena un operatore sarà disponibile.

Lasciaci il tuo numero di telefono. Ti chiameremo non appena un operatore sarà disponibile.


Laissez-nous votre numéro de téléphone. Nous vous appellerons dès qu’un de nos conseillers sera disponible.

Laissez-nous votre numéro de téléphone. Nous vous appellerons dès qu’un de nos conseillers sera disponible.