test
Via Provinciale Sud, 5 - Bagnolo in Piano (RE) Italy
itfren

SINGLE WALL IN AISI 316L STAINLESS STEEL WITH OVAL SECTION

Oval Series
Material specification
Inside diameter (mm): 130(150×100) •150(170×120) •180(200×150) •200(230×150) •250(295×180) •300(355×210)•350(395×280)•400(500×300)
Inner surface 0.5 mm nominal thickness

Quality 1.4404 (AISI 316L stainless steel)

Surface thermal resistance m2K/W at 200°C Without insulation = 0.00
Joints The product necessitates the locking clamp. To not declass the product, if sealants are going to be used, it is better to use those with a temperature class higher than 1000°C
Roughness 1 mm average value

 

General information
Installation Internal Yes

External NO it is not rain proof

Fields of application Pipes and flues connected to blown air and atmospheric type B appliances, fireplaces, stoves, kitchen hoods, ovens and ventilation ducts.
Permitted fuels T600 Gas, Diesel oil, LPG, Pellets and Firewood
Conservation In environments with a non-corrosive atmosphere
Product warranty As per the 99/44/EC directive
Dangerous substances None
Freezing-thawing resistance Meets UNI EN 1856-1
Accidental contact Protective shields must be used when surface temperature is greater than 70°C
Storage Do not store the material near ferrous materials, premises must be dry and protected against the elements
Usage limits Do not use stainless steel flue systems for premises such as laundries, dye houses, furriers, printer’s, beauty salons or where there are halogen or chromium vapours/fumes.
Product designation as per the EN 1856-2 standard Pipe
No. of the standard EN 1856-2
Temperature levela T600
Pressure level N1
Resistance to condensation D
Resistance to corrosion V2
Thickness of the inner surface L50050
Resistance to fire from inside and distance from combustible materials G

 

Performance required according to the designation
Temperature level T600 working with a nominal fumes temperature at less than 600°C
Pressure level N1 working with a positive and negative pressure up to 40Pa. Permitted loss less than 2.0l/sm2
Resistance to condensation D working with dry fumes
Resistance to corrosion V2 working with Gas-Diesel oil-LPG-Pellets-Firewood
Specification of the inner surface L50 1.4404 (AISI 316L stainless steel)
Thickness of the inner surface 050 0.5 mm nominal thickness
Resistance to fire from inside G resistant to fire from inside
Distance from combustible materials To put inside an equipment compartment, brick chimney

INSTALLATION INSTRUCTIONS

Ovale-installazione

  • Position the elements as shown by the arrow printed on the label and on the piece.
  • When using T600_N1_D use the product without the aid of silicones or sealants.
  • Once the pieces are in place, mount and tighten the locking clamp on each join.
  • Avoid the build-up of condensation or soot which could be the cause of corrosion. Also avoid horizontal sections; nonetheless install the elements with the longitudinal welding facing up (3% gradient).

ESSENTIAL FEATURES

Resistance to the wind load:

  • Distance between wall brackets: NPD m
  • Free length from the last bracket: NPD m

Compressive strength:

  • Linear elements’ maximum load: NPD
  • Maximum load of a straight fitting at 90°: NPD
  • Maximum load of the wall chimney support: NPD

30m Tensile and bending strength (linear elements):

  • Maximum load at traction (element connection means and chimney connections): NPD
  • Non-vertical installations: max. 90°
  • Non-vertical installations: distance between wall chimney supports = NPD

Traction and bending strength (non-linear elements):

  • Non-vertical installations: NPD

FLUE SYSTEM MAINTENANCE

Scheduled maintenance carried out by qualified personnel:

  • Unless standards dictate otherwise or different agreements are reached with the user, the following maintenance schedule is advisable:
    • gaseous fuels: 1 / year;
    • liquid fuels: 1 / 6 months;
    • solid fuels: 1 / month.
  • Clean the smoke duct with a soft plastic brush or sponge as well as the equipment compartment for pipe supply and ventilation, the inspection fitting and chimney and also make sure the smoke/fumes and condensates etc., are flowing freely.

SYSTEM COMPONENTS

1 M LINEAR ELEMENT

995 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.

Ovale-elemento-lineare

Codice Dn A B C D
4260 0130 130 100 150 50 995
4260 0150 150 120 170 50 995
4260 0180 180 150 200 50 995
4260 0200 200 150 225 50 995
4260 0250 250 180 295 50 995
4260 0300 300 210 355 50 995
4260 0350 350 280 395 50 995
4260 0400 400 300 500 50 995

0.5 M LINEAR ELEMENT

495 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.

Codice Dn A B C D
4255 0130 130 100 150 50 495
4255 0150 150 120 170 50 495
4255 0180 180 150 200 50 495
4255 0200 200 150 225 50 495
4255 0250 250 180 295 50 495
4255 0300 300 210 355 50 495
4255 0350 350 280 395 50 495
4255 0400 400 300 500 50 495

0.25 M LINEAR ELEMENT

245 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.

Codice Dn A B C D
4252 0130 130 100 150 50 245
4252 0150 150 120 170 50 245
4252 0180 180 150 200 50 245
4252 0200 200 150 225 50 245
4252 0250 250 180 295 50 245
4252 0300 300 210 355 50 245
4252 0350 350 280 395 50 245
4252 0400 400 300 500 50 245

LOCKING CLAMP

This component is necessary for the joining of elements; it guarantees greater stability to the system.
Ovale-fascetta-bloccaggio

Codice Dn A B C
4262 0130 130 100 150 50
4262 0150 150 120 170 50
4262 0180 180 150 200 50
4262 0200 200 150 225 50
4262 0250 250 180 295 50
4262 0300 300 210 355 50
4262 0350 350 280 395 50
4262 0400 400 300 500 50

STRAIGHT FITTING AT 90°

With this component the chimney and flue can be connected to the smoke duct at 90°.

Ovale-raccordo-retto-90

Codice Dn A B C D E
4263 0130 130 100 150 50 330 50
4263 0150 150 120 170 50 330 50
4263 0180 180 150 200 50 330 50
4263 0200 200 150 225 50 400 50
4263 0250 250 180 295 50 500 50
4263 0300 300 210 355 50 500 50
4263 0350 350 280 395 50 600 50
4263 0400 400 300 500 50 600 50

EAVES PLATE

To be placed at the base of the chimney. The condensation discharge is made in stainless steel, ¾” thread.

Ovale-gocciolatoio

Codice Dn A B C
4264 0130 130 100 150 100
4264 0150 150 120 170 100
4264 0180 180 150 200 100
4264 0200 200 150 225 100
4264 0250 250 180 295 100
4264 0300 300 210 355 100
4264 0350 350 280 395 100
4264 0400 400 300 500 100

CHINESE CHIMNEY CAP (WINDPROOF)

Component to place on the top; it protects against the rain, snow and wind.

Ovale-testa-camino-cinese

Codice Dn A B C D E F G
4277 0130 130 100 150 50 100 250 160 210
4277 0150 150 120 170 50 100 250 180 230
4277 0180 180 150 200 50 100 250 210 260
4277 0200 200 150 225 50 100 250 210 285
4277 0250 250 180 295 50 100 250 240 355
4277 0300 300 210 355 50 100 330 270 415
4277 0350 350 280 395 50 100 330 340 455
4277 0400 400 300 500 50 100 330 360 560

ADAPTER FROM OVAL FEMALE TO ROUND MALE

With this component you can go from an oval section to a round section.

Ovale-riduzione-femmina-maschio

Codice Dn A B C D
4297 0130 130 100 150 40 250
4297 0150 150 120 170 40 250
4297 0180 180 150 200 40 300
4297 0200 200 150 225 40 300
4297 0250 250 180 295 40 400
4297 0300 300 210 355 40 400
4297 0350 350 280 395 40 500
4297 0400 400 300 500 40 500

45° CURVE (ROTATES ON THE LONG SIDE)

Thanks to this component the vertical axis of the chimney and flue can be slanted 45°.

Ovale-curva-45-lato-lungo

Codice Dn A B C D
4266 0130 130 100 150 50 100
4266 0150 150 120 170 50 100
4266 0180 180 150 200 50 150
4266 0200 200 150 225 50 150
4266 0250 250 180 295 50 150
4266 0300 300 210 355 50 150
4266 0350 350 280 395 50 200
4266 0400 400 300 500 50 200

45° CURVE (ROTATES ON THE SHORT SIDE)

Thanks to this component the vertical axis of the chimney and flue can be slanted 45°.

Ovale-curva-45-lato-corto

Codice Dn A B C D
4267 0130 130 100 150 50 100
4267 0150 150 120 170 50 100
4267 0180 180 150 200 50 150
4267 0200 200 150 225 50 150
4267 0250 250 180 295 50 150
4267 0300 300 210 355 50 150
4267 0350 350 280 395 50 200
4267 0400 400 300 500 50 200

MAIN FEATURES
  • Made in AISI 316L BA stainless steel, 0.5 mm thick;
  • oval section;
  • It adapts to all situations;
  • Quick and easy to mount;
  • Advantageous;
  • Complete range
category index 
Clear Filters
MAT SERIES – AISI 316L STAINLESS STEEL QUICK COUPLING SINGLE WALL WITH LOCKING CLAMP
MAT SERIES – AISI 316L STAINLESS STEEL QUICK COUPLING SINGLE WALL WITH LOCKING CLAMP
ACCESSORIES – COMPONENTS FOR SUPPORTING AND FIXING CHIMNEYS
ACCESSORIES – COMPONENTS FOR SUPPORTING AND FIXING CHIMNEYS
OVAL SERIES – SINGLE WALL IN AISI 316L STAINLESS STEEL WITH OVAL SECTION
OVAL SERIES – SINGLE WALL IN AISI 316L STAINLESS STEEL WITH OVAL SECTION
FLEX SERIES – FLEXIBLE WITH SMOOTH INNER SURFACE
FLEX SERIES – FLEXIBLE WITH SMOOTH INNER SURFACE
INSULATION – LAGGING FOR FLUE SYSTEMS IN ROLLS AND/OR CUPELS
INSULATION – LAGGING FOR FLUE SYSTEMS IN ROLLS AND/OR CUPELS
MAIN FEATURES
  • Made in AISI 316L BA stainless steel, 0.5 mm thick;
  • oval section;
  • It adapts to all situations;
  • Quick and easy to mount;
  • Advantageous;
  • Complete range
Material specification
Inside diameter (mm): 130(150×100) •150(170×120) •180(200×150) •200(230×150) •250(295×180) •300(355×210)•350(395×280)•400(500×300)
Inner surface 0.5 mm nominal thickness

Quality 1.4404 (AISI 316L stainless steel)

Surface thermal resistance m2K/W at 200°C Without insulation = 0.00
Joints The product necessitates the locking clamp. To not declass the product, if sealants are going to be used, it is better to use those with a temperature class higher than 1000°C
Roughness 1 mm average value

 

General information
Installation Internal Yes

External NO it is not rain proof

Fields of application Pipes and flues connected to blown air and atmospheric type B appliances, fireplaces, stoves, kitchen hoods, ovens and ventilation ducts.
Permitted fuels T600 Gas, Diesel oil, LPG, Pellets and Firewood
Conservation In environments with a non-corrosive atmosphere
Product warranty As per the 99/44/EC directive
Dangerous substances None
Freezing-thawing resistance Meets UNI EN 1856-1
Accidental contact Protective shields must be used when surface temperature is greater than 70°C
Storage Do not store the material near ferrous materials, premises must be dry and protected against the elements
Usage limits Do not use stainless steel flue systems for premises such as laundries, dye houses, furriers, printer’s, beauty salons or where there are halogen or chromium vapours/fumes.
Product designation as per the EN 1856-2 standard Pipe
No. of the standard EN 1856-2
Temperature levela T600
Pressure level N1
Resistance to condensation D
Resistance to corrosion V2
Thickness of the inner surface L50050
Resistance to fire from inside and distance from combustible materials G

 

Performance required according to the designation
Temperature level T600 working with a nominal fumes temperature at less than 600°C
Pressure level N1 working with a positive and negative pressure up to 40Pa. Permitted loss less than 2.0l/sm2
Resistance to condensation D working with dry fumes
Resistance to corrosion V2 working with Gas-Diesel oil-LPG-Pellets-Firewood
Specification of the inner surface L50 1.4404 (AISI 316L stainless steel)
Thickness of the inner surface 050 0.5 mm nominal thickness
Resistance to fire from inside G resistant to fire from inside
Distance from combustible materials To put inside an equipment compartment, brick chimney

INSTALLATION INSTRUCTIONS

Ovale-installazione

  • Position the elements as shown by the arrow printed on the label and on the piece.
  • When using T600_N1_D use the product without the aid of silicones or sealants.
  • Once the pieces are in place, mount and tighten the locking clamp on each join.
  • Avoid the build-up of condensation or soot which could be the cause of corrosion. Also avoid horizontal sections; nonetheless install the elements with the longitudinal welding facing up (3% gradient).

ESSENTIAL FEATURES

Resistance to the wind load:

  • Distance between wall brackets: NPD m
  • Free length from the last bracket: NPD m

Compressive strength:

  • Linear elements’ maximum load: NPD
  • Maximum load of a straight fitting at 90°: NPD
  • Maximum load of the wall chimney support: NPD

30m Tensile and bending strength (linear elements):

  • Maximum load at traction (element connection means and chimney connections): NPD
  • Non-vertical installations: max. 90°
  • Non-vertical installations: distance between wall chimney supports = NPD

Traction and bending strength (non-linear elements):

  • Non-vertical installations: NPD

FLUE SYSTEM MAINTENANCE

Scheduled maintenance carried out by qualified personnel:

  • Unless standards dictate otherwise or different agreements are reached with the user, the following maintenance schedule is advisable:
    • gaseous fuels: 1 / year;
    • liquid fuels: 1 / 6 months;
    • solid fuels: 1 / month.
  • Clean the smoke duct with a soft plastic brush or sponge as well as the equipment compartment for pipe supply and ventilation, the inspection fitting and chimney and also make sure the smoke/fumes and condensates etc., are flowing freely.

SYSTEM COMPONENTS

1 M LINEAR ELEMENT

995 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.

Ovale-elemento-lineare

Codice Dn A B C D
4260 0130 130 100 150 50 995
4260 0150 150 120 170 50 995
4260 0180 180 150 200 50 995
4260 0200 200 150 225 50 995
4260 0250 250 180 295 50 995
4260 0300 300 210 355 50 995
4260 0350 350 280 395 50 995
4260 0400 400 300 500 50 995

0.5 M LINEAR ELEMENT

495 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.

Codice Dn A B C D
4255 0130 130 100 150 50 495
4255 0150 150 120 170 50 495
4255 0180 180 150 200 50 495
4255 0200 200 150 225 50 495
4255 0250 250 180 295 50 495
4255 0300 300 210 355 50 495
4255 0350 350 280 395 50 495
4255 0400 400 300 500 50 495

0.25 M LINEAR ELEMENT

245 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.

Codice Dn A B C D
4252 0130 130 100 150 50 245
4252 0150 150 120 170 50 245
4252 0180 180 150 200 50 245
4252 0200 200 150 225 50 245
4252 0250 250 180 295 50 245
4252 0300 300 210 355 50 245
4252 0350 350 280 395 50 245
4252 0400 400 300 500 50 245

LOCKING CLAMP

This component is necessary for the joining of elements; it guarantees greater stability to the system.
Ovale-fascetta-bloccaggio

Codice Dn A B C
4262 0130 130 100 150 50
4262 0150 150 120 170 50
4262 0180 180 150 200 50
4262 0200 200 150 225 50
4262 0250 250 180 295 50
4262 0300 300 210 355 50
4262 0350 350 280 395 50
4262 0400 400 300 500 50

STRAIGHT FITTING AT 90°

With this component the chimney and flue can be connected to the smoke duct at 90°.

Ovale-raccordo-retto-90

Codice Dn A B C D E
4263 0130 130 100 150 50 330 50
4263 0150 150 120 170 50 330 50
4263 0180 180 150 200 50 330 50
4263 0200 200 150 225 50 400 50
4263 0250 250 180 295 50 500 50
4263 0300 300 210 355 50 500 50
4263 0350 350 280 395 50 600 50
4263 0400 400 300 500 50 600 50

EAVES PLATE

To be placed at the base of the chimney. The condensation discharge is made in stainless steel, ¾” thread.

Ovale-gocciolatoio

Codice Dn A B C
4264 0130 130 100 150 100
4264 0150 150 120 170 100
4264 0180 180 150 200 100
4264 0200 200 150 225 100
4264 0250 250 180 295 100
4264 0300 300 210 355 100
4264 0350 350 280 395 100
4264 0400 400 300 500 100

CHINESE CHIMNEY CAP (WINDPROOF)

Component to place on the top; it protects against the rain, snow and wind.

Ovale-testa-camino-cinese

Codice Dn A B C D E F G
4277 0130 130 100 150 50 100 250 160 210
4277 0150 150 120 170 50 100 250 180 230
4277 0180 180 150 200 50 100 250 210 260
4277 0200 200 150 225 50 100 250 210 285
4277 0250 250 180 295 50 100 250 240 355
4277 0300 300 210 355 50 100 330 270 415
4277 0350 350 280 395 50 100 330 340 455
4277 0400 400 300 500 50 100 330 360 560

ADAPTER FROM OVAL FEMALE TO ROUND MALE

With this component you can go from an oval section to a round section.

Ovale-riduzione-femmina-maschio

Codice Dn A B C D
4297 0130 130 100 150 40 250
4297 0150 150 120 170 40 250
4297 0180 180 150 200 40 300
4297 0200 200 150 225 40 300
4297 0250 250 180 295 40 400
4297 0300 300 210 355 40 400
4297 0350 350 280 395 40 500
4297 0400 400 300 500 40 500

45° CURVE (ROTATES ON THE LONG SIDE)

Thanks to this component the vertical axis of the chimney and flue can be slanted 45°.

Ovale-curva-45-lato-lungo

Codice Dn A B C D
4266 0130 130 100 150 50 100
4266 0150 150 120 170 50 100
4266 0180 180 150 200 50 150
4266 0200 200 150 225 50 150
4266 0250 250 180 295 50 150
4266 0300 300 210 355 50 150
4266 0350 350 280 395 50 200
4266 0400 400 300 500 50 200

45° CURVE (ROTATES ON THE SHORT SIDE)

Thanks to this component the vertical axis of the chimney and flue can be slanted 45°.

Ovale-curva-45-lato-corto

Codice Dn A B C D
4267 0130 130 100 150 50 100
4267 0150 150 120 170 50 100
4267 0180 180 150 200 50 150
4267 0200 200 150 225 50 150
4267 0250 250 180 295 50 150
4267 0300 300 210 355 50 150
4267 0350 350 280 395 50 200
4267 0400 400 300 500 50 200

Clear Filters
MAT SERIES – AISI 316L STAINLESS STEEL QUICK COUPLING SINGLE WALL WITH LOCKING CLAMP
MAT SERIES – AISI 316L STAINLESS STEEL QUICK COUPLING SINGLE WALL WITH LOCKING CLAMP
ACCESSORIES – COMPONENTS FOR SUPPORTING AND FIXING CHIMNEYS
ACCESSORIES – COMPONENTS FOR SUPPORTING AND FIXING CHIMNEYS
OVAL SERIES – SINGLE WALL IN AISI 316L STAINLESS STEEL WITH OVAL SECTION
OVAL SERIES – SINGLE WALL IN AISI 316L STAINLESS STEEL WITH OVAL SECTION
FLEX SERIES – FLEXIBLE WITH SMOOTH INNER SURFACE
FLEX SERIES – FLEXIBLE WITH SMOOTH INNER SURFACE
INSULATION – LAGGING FOR FLUE SYSTEMS IN ROLLS AND/OR CUPELS
INSULATION – LAGGING FOR FLUE SYSTEMS IN ROLLS AND/OR CUPELS

Made by Quantik 🚀