Material specification | |
Inside diameter (mm): | 130(150×100) •150(170×120) •180(200×150) •200(230×150) •250(295×180) •300(355×210)•350(395×280)•400(500×300) |
Inner surface | 0.5 mm nominal thickness
Quality 1.4404 (AISI 316L stainless steel) |
Surface thermal resistance m2K/W at 200°C | Without insulation = 0.00 |
Joints | The product necessitates the locking clamp. To not declass the product, if sealants are going to be used, it is better to use those with a temperature class higher than 1000°C |
Roughness | 1 mm average value |
General information | |
Installation | Internal Yes
External NO it is not rain proof |
Fields of application | Pipes and flues connected to blown air and atmospheric type B appliances, fireplaces, stoves, kitchen hoods, ovens and ventilation ducts. |
Permitted fuels | T600 Gas, Diesel oil, LPG, Pellets and Firewood |
Conservation | In environments with a non-corrosive atmosphere |
Product warranty | As per the 99/44/EC directive |
Dangerous substances | None |
Freezing-thawing resistance | Meets UNI EN 1856-1 |
Accidental contact | Protective shields must be used when surface temperature is greater than 70°C |
Storage | Do not store the material near ferrous materials, premises must be dry and protected against the elements |
Usage limits | Do not use stainless steel flue systems for premises such as laundries, dye houses, furriers, printer’s, beauty salons or where there are halogen or chromium vapours/fumes. |
Product designation as per the EN 1856-2 standard | Pipe |
No. of the standard | EN 1856-2 |
Temperature levela | T600 |
Pressure level | N1 |
Resistance to condensation | D |
Resistance to corrosion | V2 |
Thickness of the inner surface | L50050 |
Resistance to fire from inside and distance from combustible materials | G |
Performance required according to the designation | ||
Temperature level | T600 | working with a nominal fumes temperature at less than 600°C |
Pressure level | N1 | working with a positive and negative pressure up to 40Pa. Permitted loss less than 2.0l/sm2 |
Resistance to condensation | D | working with dry fumes |
Resistance to corrosion | V2 | working with Gas-Diesel oil-LPG-Pellets-Firewood |
Specification of the inner surface | L50 | 1.4404 (AISI 316L stainless steel) |
Thickness of the inner surface | 050 | 0.5 mm nominal thickness |
Resistance to fire from inside | G | resistant to fire from inside |
Distance from combustible materials | – | To put inside an equipment compartment, brick chimney |
INSTALLATION INSTRUCTIONS
- Position the elements as shown by the arrow printed on the label and on the piece.
- When using T600_N1_D use the product without the aid of silicones or sealants.
- Once the pieces are in place, mount and tighten the locking clamp on each join.
- Avoid the build-up of condensation or soot which could be the cause of corrosion. Also avoid horizontal sections; nonetheless install the elements with the longitudinal welding facing up (3% gradient).
ESSENTIAL FEATURES
Resistance to the wind load:
- Distance between wall brackets: NPD m
- Free length from the last bracket: NPD m
Compressive strength:
- Linear elements’ maximum load: NPD
- Maximum load of a straight fitting at 90°: NPD
- Maximum load of the wall chimney support: NPD
30m Tensile and bending strength (linear elements):
- Maximum load at traction (element connection means and chimney connections): NPD
- Non-vertical installations: max. 90°
- Non-vertical installations: distance between wall chimney supports = NPD
Traction and bending strength (non-linear elements):
- Non-vertical installations: NPD
FLUE SYSTEM MAINTENANCE
Scheduled maintenance carried out by qualified personnel:
- Unless standards dictate otherwise or different agreements are reached with the user, the following maintenance schedule is advisable:
- gaseous fuels: 1 / year;
- liquid fuels: 1 / 6 months;
- solid fuels: 1 / month.
- Clean the smoke duct with a soft plastic brush or sponge as well as the equipment compartment for pipe supply and ventilation, the inspection fitting and chimney and also make sure the smoke/fumes and condensates etc., are flowing freely.
SYSTEM COMPONENTS
1 M LINEAR ELEMENT
995 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.
Codice | Dn | A | B | C | D |
4260 0130 | 130 | 100 | 150 | 50 | 995 |
4260 0150 | 150 | 120 | 170 | 50 | 995 |
4260 0180 | 180 | 150 | 200 | 50 | 995 |
4260 0200 | 200 | 150 | 225 | 50 | 995 |
4260 0250 | 250 | 180 | 295 | 50 | 995 |
4260 0300 | 300 | 210 | 355 | 50 | 995 |
4260 0350 | 350 | 280 | 395 | 50 | 995 |
4260 0400 | 400 | 300 | 500 | 50 | 995 |
0.5 M LINEAR ELEMENT
495 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.
Codice | Dn | A | B | C | D |
4255 0130 | 130 | 100 | 150 | 50 | 495 |
4255 0150 | 150 | 120 | 170 | 50 | 495 |
4255 0180 | 180 | 150 | 200 | 50 | 495 |
4255 0200 | 200 | 150 | 225 | 50 | 495 |
4255 0250 | 250 | 180 | 295 | 50 | 495 |
4255 0300 | 300 | 210 | 355 | 50 | 495 |
4255 0350 | 350 | 280 | 395 | 50 | 495 |
4255 0400 | 400 | 300 | 500 | 50 | 495 |
0.25 M LINEAR ELEMENT
245 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.
Codice | Dn | A | B | C | D |
4252 0130 | 130 | 100 | 150 | 50 | 245 |
4252 0150 | 150 | 120 | 170 | 50 | 245 |
4252 0180 | 180 | 150 | 200 | 50 | 245 |
4252 0200 | 200 | 150 | 225 | 50 | 245 |
4252 0250 | 250 | 180 | 295 | 50 | 245 |
4252 0300 | 300 | 210 | 355 | 50 | 245 |
4252 0350 | 350 | 280 | 395 | 50 | 245 |
4252 0400 | 400 | 300 | 500 | 50 | 245 |
LOCKING CLAMP
This component is necessary for the joining of elements; it guarantees greater stability to the system.
Codice | Dn | A | B | C |
4262 0130 | 130 | 100 | 150 | 50 |
4262 0150 | 150 | 120 | 170 | 50 |
4262 0180 | 180 | 150 | 200 | 50 |
4262 0200 | 200 | 150 | 225 | 50 |
4262 0250 | 250 | 180 | 295 | 50 |
4262 0300 | 300 | 210 | 355 | 50 |
4262 0350 | 350 | 280 | 395 | 50 |
4262 0400 | 400 | 300 | 500 | 50 |
STRAIGHT FITTING AT 90°
With this component the chimney and flue can be connected to the smoke duct at 90°.
Codice | Dn | A | B | C | D | E |
4263 0130 | 130 | 100 | 150 | 50 | 330 | 50 |
4263 0150 | 150 | 120 | 170 | 50 | 330 | 50 |
4263 0180 | 180 | 150 | 200 | 50 | 330 | 50 |
4263 0200 | 200 | 150 | 225 | 50 | 400 | 50 |
4263 0250 | 250 | 180 | 295 | 50 | 500 | 50 |
4263 0300 | 300 | 210 | 355 | 50 | 500 | 50 |
4263 0350 | 350 | 280 | 395 | 50 | 600 | 50 |
4263 0400 | 400 | 300 | 500 | 50 | 600 | 50 |
EAVES PLATE
To be placed at the base of the chimney. The condensation discharge is made in stainless steel, ¾” thread.
Codice | Dn | A | B | C |
4264 0130 | 130 | 100 | 150 | 100 |
4264 0150 | 150 | 120 | 170 | 100 |
4264 0180 | 180 | 150 | 200 | 100 |
4264 0200 | 200 | 150 | 225 | 100 |
4264 0250 | 250 | 180 | 295 | 100 |
4264 0300 | 300 | 210 | 355 | 100 |
4264 0350 | 350 | 280 | 395 | 100 |
4264 0400 | 400 | 300 | 500 | 100 |
CHINESE CHIMNEY CAP (WINDPROOF)
Component to place on the top; it protects against the rain, snow and wind.
Codice | Dn | A | B | C | D | E | F | G |
4277 0130 | 130 | 100 | 150 | 50 | 100 | 250 | 160 | 210 |
4277 0150 | 150 | 120 | 170 | 50 | 100 | 250 | 180 | 230 |
4277 0180 | 180 | 150 | 200 | 50 | 100 | 250 | 210 | 260 |
4277 0200 | 200 | 150 | 225 | 50 | 100 | 250 | 210 | 285 |
4277 0250 | 250 | 180 | 295 | 50 | 100 | 250 | 240 | 355 |
4277 0300 | 300 | 210 | 355 | 50 | 100 | 330 | 270 | 415 |
4277 0350 | 350 | 280 | 395 | 50 | 100 | 330 | 340 | 455 |
4277 0400 | 400 | 300 | 500 | 50 | 100 | 330 | 360 | 560 |
ADAPTER FROM OVAL FEMALE TO ROUND MALE
With this component you can go from an oval section to a round section.
Codice | Dn | A | B | C | D |
4297 0130 | 130 | 100 | 150 | 40 | 250 |
4297 0150 | 150 | 120 | 170 | 40 | 250 |
4297 0180 | 180 | 150 | 200 | 40 | 300 |
4297 0200 | 200 | 150 | 225 | 40 | 300 |
4297 0250 | 250 | 180 | 295 | 40 | 400 |
4297 0300 | 300 | 210 | 355 | 40 | 400 |
4297 0350 | 350 | 280 | 395 | 40 | 500 |
4297 0400 | 400 | 300 | 500 | 40 | 500 |
45° CURVE (ROTATES ON THE LONG SIDE)
Thanks to this component the vertical axis of the chimney and flue can be slanted 45°.
Codice | Dn | A | B | C | D |
4266 0130 | 130 | 100 | 150 | 50 | 100 |
4266 0150 | 150 | 120 | 170 | 50 | 100 |
4266 0180 | 180 | 150 | 200 | 50 | 150 |
4266 0200 | 200 | 150 | 225 | 50 | 150 |
4266 0250 | 250 | 180 | 295 | 50 | 150 |
4266 0300 | 300 | 210 | 355 | 50 | 150 |
4266 0350 | 350 | 280 | 395 | 50 | 200 |
4266 0400 | 400 | 300 | 500 | 50 | 200 |
45° CURVE (ROTATES ON THE SHORT SIDE)
Thanks to this component the vertical axis of the chimney and flue can be slanted 45°.
Codice | Dn | A | B | C | D |
4267 0130 | 130 | 100 | 150 | 50 | 100 |
4267 0150 | 150 | 120 | 170 | 50 | 100 |
4267 0180 | 180 | 150 | 200 | 50 | 150 |
4267 0200 | 200 | 150 | 225 | 50 | 150 |
4267 0250 | 250 | 180 | 295 | 50 | 150 |
4267 0300 | 300 | 210 | 355 | 50 | 150 |
4267 0350 | 350 | 280 | 395 | 50 | 200 |
4267 0400 | 400 | 300 | 500 | 50 | 200 |
MAIN FEATURES
- Made in AISI 316L BA stainless steel, 0.5 mm thick;
- oval section;
- It adapts to all situations;
- Quick and easy to mount;
- Advantageous;
- Complete range
MAIN FEATURES
- Made in AISI 316L BA stainless steel, 0.5 mm thick;
- oval section;
- It adapts to all situations;
- Quick and easy to mount;
- Advantageous;
- Complete range
Material specification | |
Inside diameter (mm): | 130(150×100) •150(170×120) •180(200×150) •200(230×150) •250(295×180) •300(355×210)•350(395×280)•400(500×300) |
Inner surface | 0.5 mm nominal thickness
Quality 1.4404 (AISI 316L stainless steel) |
Surface thermal resistance m2K/W at 200°C | Without insulation = 0.00 |
Joints | The product necessitates the locking clamp. To not declass the product, if sealants are going to be used, it is better to use those with a temperature class higher than 1000°C |
Roughness | 1 mm average value |
General information | |
Installation | Internal Yes
External NO it is not rain proof |
Fields of application | Pipes and flues connected to blown air and atmospheric type B appliances, fireplaces, stoves, kitchen hoods, ovens and ventilation ducts. |
Permitted fuels | T600 Gas, Diesel oil, LPG, Pellets and Firewood |
Conservation | In environments with a non-corrosive atmosphere |
Product warranty | As per the 99/44/EC directive |
Dangerous substances | None |
Freezing-thawing resistance | Meets UNI EN 1856-1 |
Accidental contact | Protective shields must be used when surface temperature is greater than 70°C |
Storage | Do not store the material near ferrous materials, premises must be dry and protected against the elements |
Usage limits | Do not use stainless steel flue systems for premises such as laundries, dye houses, furriers, printer’s, beauty salons or where there are halogen or chromium vapours/fumes. |
Product designation as per the EN 1856-2 standard | Pipe |
No. of the standard | EN 1856-2 |
Temperature levela | T600 |
Pressure level | N1 |
Resistance to condensation | D |
Resistance to corrosion | V2 |
Thickness of the inner surface | L50050 |
Resistance to fire from inside and distance from combustible materials | G |
Performance required according to the designation | ||
Temperature level | T600 | working with a nominal fumes temperature at less than 600°C |
Pressure level | N1 | working with a positive and negative pressure up to 40Pa. Permitted loss less than 2.0l/sm2 |
Resistance to condensation | D | working with dry fumes |
Resistance to corrosion | V2 | working with Gas-Diesel oil-LPG-Pellets-Firewood |
Specification of the inner surface | L50 | 1.4404 (AISI 316L stainless steel) |
Thickness of the inner surface | 050 | 0.5 mm nominal thickness |
Resistance to fire from inside | G | resistant to fire from inside |
Distance from combustible materials | – | To put inside an equipment compartment, brick chimney |
INSTALLATION INSTRUCTIONS
- Position the elements as shown by the arrow printed on the label and on the piece.
- When using T600_N1_D use the product without the aid of silicones or sealants.
- Once the pieces are in place, mount and tighten the locking clamp on each join.
- Avoid the build-up of condensation or soot which could be the cause of corrosion. Also avoid horizontal sections; nonetheless install the elements with the longitudinal welding facing up (3% gradient).
ESSENTIAL FEATURES
Resistance to the wind load:
- Distance between wall brackets: NPD m
- Free length from the last bracket: NPD m
Compressive strength:
- Linear elements’ maximum load: NPD
- Maximum load of a straight fitting at 90°: NPD
- Maximum load of the wall chimney support: NPD
30m Tensile and bending strength (linear elements):
- Maximum load at traction (element connection means and chimney connections): NPD
- Non-vertical installations: max. 90°
- Non-vertical installations: distance between wall chimney supports = NPD
Traction and bending strength (non-linear elements):
- Non-vertical installations: NPD
FLUE SYSTEM MAINTENANCE
Scheduled maintenance carried out by qualified personnel:
- Unless standards dictate otherwise or different agreements are reached with the user, the following maintenance schedule is advisable:
- gaseous fuels: 1 / year;
- liquid fuels: 1 / 6 months;
- solid fuels: 1 / month.
- Clean the smoke duct with a soft plastic brush or sponge as well as the equipment compartment for pipe supply and ventilation, the inspection fitting and chimney and also make sure the smoke/fumes and condensates etc., are flowing freely.
SYSTEM COMPONENTS
1 M LINEAR ELEMENT
995 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.
Codice | Dn | A | B | C | D |
4260 0130 | 130 | 100 | 150 | 50 | 995 |
4260 0150 | 150 | 120 | 170 | 50 | 995 |
4260 0180 | 180 | 150 | 200 | 50 | 995 |
4260 0200 | 200 | 150 | 225 | 50 | 995 |
4260 0250 | 250 | 180 | 295 | 50 | 995 |
4260 0300 | 300 | 210 | 355 | 50 | 995 |
4260 0350 | 350 | 280 | 395 | 50 | 995 |
4260 0400 | 400 | 300 | 500 | 50 | 995 |
0.5 M LINEAR ELEMENT
495 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.
Codice | Dn | A | B | C | D |
4255 0130 | 130 | 100 | 150 | 50 | 495 |
4255 0150 | 150 | 120 | 170 | 50 | 495 |
4255 0180 | 180 | 150 | 200 | 50 | 495 |
4255 0200 | 200 | 150 | 225 | 50 | 495 |
4255 0250 | 250 | 180 | 295 | 50 | 495 |
4255 0300 | 300 | 210 | 355 | 50 | 495 |
4255 0350 | 350 | 280 | 395 | 50 | 495 |
4255 0400 | 400 | 300 | 500 | 50 | 495 |
0.25 M LINEAR ELEMENT
245 mm high modular component to use on vertical or sub-horizontal sections. It must be applied as shown by the arrow printed on the label.
Codice | Dn | A | B | C | D |
4252 0130 | 130 | 100 | 150 | 50 | 245 |
4252 0150 | 150 | 120 | 170 | 50 | 245 |
4252 0180 | 180 | 150 | 200 | 50 | 245 |
4252 0200 | 200 | 150 | 225 | 50 | 245 |
4252 0250 | 250 | 180 | 295 | 50 | 245 |
4252 0300 | 300 | 210 | 355 | 50 | 245 |
4252 0350 | 350 | 280 | 395 | 50 | 245 |
4252 0400 | 400 | 300 | 500 | 50 | 245 |
LOCKING CLAMP
This component is necessary for the joining of elements; it guarantees greater stability to the system.
Codice | Dn | A | B | C |
4262 0130 | 130 | 100 | 150 | 50 |
4262 0150 | 150 | 120 | 170 | 50 |
4262 0180 | 180 | 150 | 200 | 50 |
4262 0200 | 200 | 150 | 225 | 50 |
4262 0250 | 250 | 180 | 295 | 50 |
4262 0300 | 300 | 210 | 355 | 50 |
4262 0350 | 350 | 280 | 395 | 50 |
4262 0400 | 400 | 300 | 500 | 50 |
STRAIGHT FITTING AT 90°
With this component the chimney and flue can be connected to the smoke duct at 90°.
Codice | Dn | A | B | C | D | E |
4263 0130 | 130 | 100 | 150 | 50 | 330 | 50 |
4263 0150 | 150 | 120 | 170 | 50 | 330 | 50 |
4263 0180 | 180 | 150 | 200 | 50 | 330 | 50 |
4263 0200 | 200 | 150 | 225 | 50 | 400 | 50 |
4263 0250 | 250 | 180 | 295 | 50 | 500 | 50 |
4263 0300 | 300 | 210 | 355 | 50 | 500 | 50 |
4263 0350 | 350 | 280 | 395 | 50 | 600 | 50 |
4263 0400 | 400 | 300 | 500 | 50 | 600 | 50 |
EAVES PLATE
To be placed at the base of the chimney. The condensation discharge is made in stainless steel, ¾” thread.
Codice | Dn | A | B | C |
4264 0130 | 130 | 100 | 150 | 100 |
4264 0150 | 150 | 120 | 170 | 100 |
4264 0180 | 180 | 150 | 200 | 100 |
4264 0200 | 200 | 150 | 225 | 100 |
4264 0250 | 250 | 180 | 295 | 100 |
4264 0300 | 300 | 210 | 355 | 100 |
4264 0350 | 350 | 280 | 395 | 100 |
4264 0400 | 400 | 300 | 500 | 100 |
CHINESE CHIMNEY CAP (WINDPROOF)
Component to place on the top; it protects against the rain, snow and wind.
Codice | Dn | A | B | C | D | E | F | G |
4277 0130 | 130 | 100 | 150 | 50 | 100 | 250 | 160 | 210 |
4277 0150 | 150 | 120 | 170 | 50 | 100 | 250 | 180 | 230 |
4277 0180 | 180 | 150 | 200 | 50 | 100 | 250 | 210 | 260 |
4277 0200 | 200 | 150 | 225 | 50 | 100 | 250 | 210 | 285 |
4277 0250 | 250 | 180 | 295 | 50 | 100 | 250 | 240 | 355 |
4277 0300 | 300 | 210 | 355 | 50 | 100 | 330 | 270 | 415 |
4277 0350 | 350 | 280 | 395 | 50 | 100 | 330 | 340 | 455 |
4277 0400 | 400 | 300 | 500 | 50 | 100 | 330 | 360 | 560 |
ADAPTER FROM OVAL FEMALE TO ROUND MALE
With this component you can go from an oval section to a round section.
Codice | Dn | A | B | C | D |
4297 0130 | 130 | 100 | 150 | 40 | 250 |
4297 0150 | 150 | 120 | 170 | 40 | 250 |
4297 0180 | 180 | 150 | 200 | 40 | 300 |
4297 0200 | 200 | 150 | 225 | 40 | 300 |
4297 0250 | 250 | 180 | 295 | 40 | 400 |
4297 0300 | 300 | 210 | 355 | 40 | 400 |
4297 0350 | 350 | 280 | 395 | 40 | 500 |
4297 0400 | 400 | 300 | 500 | 40 | 500 |
45° CURVE (ROTATES ON THE LONG SIDE)
Thanks to this component the vertical axis of the chimney and flue can be slanted 45°.
Codice | Dn | A | B | C | D |
4266 0130 | 130 | 100 | 150 | 50 | 100 |
4266 0150 | 150 | 120 | 170 | 50 | 100 |
4266 0180 | 180 | 150 | 200 | 50 | 150 |
4266 0200 | 200 | 150 | 225 | 50 | 150 |
4266 0250 | 250 | 180 | 295 | 50 | 150 |
4266 0300 | 300 | 210 | 355 | 50 | 150 |
4266 0350 | 350 | 280 | 395 | 50 | 200 |
4266 0400 | 400 | 300 | 500 | 50 | 200 |
45° CURVE (ROTATES ON THE SHORT SIDE)
Thanks to this component the vertical axis of the chimney and flue can be slanted 45°.
Codice | Dn | A | B | C | D |
4267 0130 | 130 | 100 | 150 | 50 | 100 |
4267 0150 | 150 | 120 | 170 | 50 | 100 |
4267 0180 | 180 | 150 | 200 | 50 | 150 |
4267 0200 | 200 | 150 | 225 | 50 | 150 |
4267 0250 | 250 | 180 | 295 | 50 | 150 |
4267 0300 | 300 | 210 | 355 | 50 | 150 |
4267 0350 | 350 | 280 | 395 | 50 | 200 |
4267 0400 | 400 | 300 | 500 | 50 | 200 |