Fibrotubi

Eterinox - Serie ovale

Eterinox – Oval series

Technical Data
Material specification
Internal diameter (mm): 130 (150×100) • 150 (170×120) • 180 (200×150) • 200 (230×150) • 250 (295×180) • 300 (355×210) • 350 (395×280) • 400 (500×300)
Inner wallNominal thickness: 0.5 mm

Grade 1.4404 (AISI 316L stainless steel)

Wall thermal resistance m²K/W at 200°C:
Without insulation = 0.00
JointsThe product requires a locking band. In order not to downgrade the product, if sealants are used, it is recommended to use those with a temperature rating above 1000°C.
Roughness: average value 1 mm
General information
InstallationInternal: Yes

External: No, not resistant to rainwater penetration

Fields of application
Ducts and flues connected to forced-air boilers, atmospheric boilers, type B appliances, fireplaces, stoves, kitchen hoods, ovens, and ventilation ducts.
Permitted fuels
T600 gas, diesel oil, LPG, pellets, and wood.
Storage: In environments where the atmosphere is non-corrosive
Product warranty: In accordance with Directive 99/44/EC
Hazardous substances: None
Freeze–thaw resistance: Compliant with UNI EN 1856-1
Accidental contact: Protective shielding is required when the wall surface temperature exceeds 70°C
Storage: Do not store the material near ferrous materials; environments must be dry and protected from weather exposure
Limitations of use: The use of stainless steel flue systems is not recommended in environments such as laundries, dry cleaners, furriers, printing facilities, beauty salons, or in any areas where halogenated or chromated vapors are present

Product designation according to EN 1856-2 standard
Duct.
Standard number
EN 1856-2
Temperature rating
T600
Pressure rating
N1
Condensate resistance
D
Corrosion resistance
V2
Internal wall thickness
L50050
Fire resistance from inside and distance to combustible materials
G

Performance requirements according to the designation
Temperature rating
T600 – operation with nominal flue gas temperature below 600°C
Pressure rating
N1
Operation with positive and negative pressure up to 40 Pa.
Permissible leakage less than 2.0 l/s·m²
Condensate resistance
D – operation with dry flue gases
Corrosion resistance
V2 – suitable for operation with gas, diesel oil, LPG, pellets, and wood.
Internal wall specification
L501.4404 (Stainless steel AISI 316L)
Internal wall thickness
050 – nominal thickness 0.5 mm
Fire resistance from inside: G
Resistant to internal fire
Distance to combustible materials
– To be installed inside a technical shaft, masonry chimney.

INSTALLATION INSTRUCTIONS

  • Position the components as indicated by the arrow stamped on the label and shown on the piece.
  • For T600_N1_D use, the product must be installed without the use of silicone or sealants.
  • After connecting the components, fit and tighten the appropriate locking clamp at each joint.
  • Avoid the accumulation of condensate or soot, which may cause corrosion. Also avoid horizontal sections and, in any case, install the elements with the longitudinal weld facing upwards (3% slope).

ESSENTIAL CHARACTERISTICS

Wind load resistance:

  • Distance between wall brackets: NPD m
  • Free length from the last bracket: NPD m

Compression resistance:

  • Maximum load for linear elements: NPD (No Performance Determined)
  • Maximum load for 90° straight fitting: NPD (No Performance Determined)
  • Maximum load for wall-mounted chimney support: NPD (No Performance Determined)

Tensile and bending resistance (straight elements):

  • Maximum tensile load (connection means of chimney elements and fittings): NPD (No Performance Determined)
  • Non-vertical installations: max. 90°
  • Non-vertical installations: distance between wall chimney supports = NPD (No Performance Determined)

Tensile and bending resistance (non-linear elements):

  • Non-vertical installations: NPD

FLUE SYSTEM MAINTENANCE

Scheduled maintenance carried out by qualified personnel:

  • Unless otherwise required by regulations or agreed with users, the following maintenance intervals are recommended:
    • Gaseous fuels: once per year;
    • Liquid fuels: once every 6 months;
    • Solid fuels: once per month.
  • Cleaning using a soft plastic brush or sponge of the flue pipe, the technical compartment for air supply and ventilation of the ducts, the inspection connection, the chimney cap; checking the free flow of flue gases and condensate, etc.

Contact us

Request information or a customized quote

"*" indicates required fields

Dati personali*

Lasciaci il tuo numero di telefono. Ti chiameremo non appena un operatore sarà disponibile.

Lasciaci il tuo numero di telefono. Ti chiameremo non appena un operatore sarà disponibile.


Laissez-nous votre numéro de téléphone. Nous vous appellerons dès qu’un de nos conseillers sera disponible.

Laissez-nous votre numéro de téléphone. Nous vous appellerons dès qu’un de nos conseillers sera disponible.