Eterinox – Mat Series

Single-wall system with quick-fit connection and locking clamp

Technical Data

Material specification
Internal diameter (mm): 80 • 100 • 120 • 130 • 140 • 150 • 160 • 180 • 200 • 230 • 250 • 300 • 350 • 400

Inner wall

Nominal thickness: 0.5 mm

Grade 1.4404 (AISI 316L stainless steel)

 Wall thermal resistance m²K/W at 200°C:
Without insulation = 0.00
 Sealing ring: Profiled ring gasket with three sealing lips in black silicone, compliant with UNI EN 14241-1
 Roughness: average value 1 mm
 
General information
Installation

Internal: Yes

External: No, not resistant to rainwater penetration

 Applications: Ducts, chimneys, flue pipes, connectors, and flue systems connected to forced-air boilers, atmospheric and pressurized boilers, type B and C appliances, condensing units, fireplaces, stoves, kitchen hoods, ovens, and ventilation ducts
Permitted fuels

T200: Gas, Diesel, LPG, Pellet

T600: Gas, Diesel, LPG, Pellet, and Wood

 Storage: In environments where the atmosphere is non-corrosive
 Product warranty: In accordance with Directive 99/44/EC
 Hazardous substances: None
 Freeze–thaw resistance: Compliant with UNI EN 1856-1
 Accidental contact: Protective shielding is required when the wall surface temperature exceeds 70°C
 Storage: Do not store the material near ferrous materials; environments must be dry and protected from weather exposure
 Limitations of use: The use of stainless steel flue systems is not recommended in environments such as laundries, dry cleaners, furriers, printing facilities, beauty salons, or in any areas where halogenated or chromated vapors are present
 
Product designation according to EN 1856-2: Duct / Flue pipe
Standard No.: EN 1856-2 / EN 856-2
Temperature level: T200 / T200
Pressure level: P1 / P1
Condensate resistance: W / W
Corrosion resistance: V2 / V2
Inner wall thickness: L50050 / L50050
Fire resistance from inside and distance from combustible materials: O O (30 mm) / M
Product designation according to EN 1856-2: Duct / Flue pipe
Standard No.: EN 1856-2 / EN 1856-2
Temperature level: T600 / T600
Pressure level: N1 / N1
Condensate resistance: D / D
Corrosion resistance: V2 / V2
Inner wall thickness: L50050 / L50050
Fire resistance from inside and distance from combustible materials: G G (600 mm) / M
Performance requirements according to the designation
Temperature levelT200

T600

Operation with nominal flue gas temperature lower than 200°C

Operation with nominal flue gas temperature lower than 600°C

Pressure levelP1

N1

Operation with positive and negative pressure up to 200 Pa.
Permissible leakage less than 0.006 l/m²

Operation with positive and negative pressure up to 40 Pa.
Permissible leakage less than 2.0 l/s·m²

Condensate resistanceW

D

Operation with wet and dry flue gases

Operation with dry flue gases

Corrosion resistance: V2 / V2
Suitable for operation with Gas, Diesel, LPG, Pellet, and Wood
Inner wall specification: L50 / L50
Nominal thickness: 0.5 mm
Inner wall thickness: O
Not resistant to internal fire
Fire resistance from inside: G
Resistant to internal fire
Distance from combustible materials(30) M

(600) M

(30) = minimum 30 mm;
M = value determined through laboratory testing

(600) = minimum 600 mm;
M = value determined through laboratory testing

INSTALLATION INSTRUCTIONS

  • Position the components as indicated by the arrow stamped on the label and shown on the piece.
  • For use at T200_P1_W, position the sealing ring in the dedicated seat located in the female socket.
  • The sealing ring must be positioned with the three lips facing towards the inside of the pipe.
  • To prevent damage and facilitate insertion, talc or soap must be used.
  • For use at T600_N1_D, use the product without the sealing ring.
  • After connecting the components, fit and tighten the appropriate locking clamp at each joint.
  • Respect compression loads and non-vertical installation requirements.
  • Avoid the accumulation of condensate or soot, which may cause corrosion. Also avoid horizontal sections and, in any case, install the elements with the longitudinal weld facing upwards (3% slope).

ESSENTIAL CHARACTERISTICS

Wind load resistance:

  • Distance between wall brackets: NPD m
  • Free length from the last bracket: NPD m

Compression resistance:

  • Maximum load for straight elements: 8 m
  • Maximum load for 90° straight connector: 8 m
  • Maximum load for wall-mounted chimney support: 8 m

Note: The values above refer to the worst-case condition. For more information, see the Mechanical Resistance Table.

Tensile and bending resistance (straight elements):

  • Maximum tensile load (connection means of elements and chimney fittings): 16 m
  • Non-vertical installations: max. 90°
  • Non-vertical installations: distance between wall chimney supports = 2 m

Tensile and bending resistance (non-linear elements):

    • Non-vertical installations: NPD

FLUE SYSTEM MAINTENANCE

Scheduled maintenance carried out by qualified personnel:

  • Unless otherwise required by regulations or agreed with users, the following maintenance intervals are recommended:
    • Gaseous fuels: once per year;
    • Liquid fuels: once every 6 months;
    • Solid fuels: once per month.
  • Cleaning using a soft plastic brush or sponge of the flue pipe, the technical compartment for air supply and ventilation of the ducts, the inspection connection, the chimney cap; checking the free flow of flue gases and condensate, etc.

Contact us

Request information or a customized quote

"*" indicates required fields

Dati personali*

Lasciaci il tuo numero di telefono. Ti chiameremo non appena un operatore sarà disponibile.

Lasciaci il tuo numero di telefono. Ti chiameremo non appena un operatore sarà disponibile.


Laissez-nous votre numéro de téléphone. Nous vous appellerons dès qu’un de nos conseillers sera disponible.

Laissez-nous votre numéro de téléphone. Nous vous appellerons dès qu’un de nos conseillers sera disponible.